A periodic inspection checks the condition of an existing electrical installation against bs 7671 the uk standard for the safety of electrical installations.
Domestic electrical inspection frequency.
Bs 7671 states the maximum intervals between inspections and an electrical inspector may specify a lower frequency based on factors such as condition and age.
The frequency of how often eicr s should be carried out varies depending on the type age and condition of the electrical installation.
The frequency of periodic inspection and testing must be determined taking into account various factors.
Reveal if any of your electrical circuits or equipment are overloaded.
Identify any defective electrical work.
A periodic inspection will.
Combined inspection test.
Periodic test and inspection.
A periodic inspection should.
For instance the maximum period between inspections and testing in an industrial environment is 3 years whereas for shops it s every 5 years.
Electrical inspection and testing hse and other organisations have produced guidance on electrical safety that is suitable for a wide range of industries and technical competencies.
The table below provides guidance on the frequency of formal inspections of electrical installations as well as routine checks.
Frequency between inspections and testing as necessary see notes below domestic general.
Frequency of testing electrical safety testing.
Change of occupancy 5 years.
Change of occupancy 10 years.
Find any potential electric shock risks and fire hazards.
Highlight any lack of earthing or bonding.
Tests are also carried out on wiring and fixed electrical equipment to check that they are safe.
Domestic accmomdation rented.
A recommendation for the interval to the first periodic inspection should be provided by the electrical installation designer and recorded on the electrical installation certificate regulation 134 2 2 in making the recommendation the designer should together with the factors listed earlier also take into account the frequency and.
Find any defective electrical work.
Most of the information produced by the hse is available for immediate download.
The 18th iet edition wiring regulations bs 7671 2018 sets out a table detailing the guidance on the frequency of formal inspections of electrical installations as well as routine checks.
Identify potential electrical shock risks and fire hazards.
Change of occupancy 5 years.
Periodic test and inspection suggested frequency general installation.
Change of occupancy 5.
Table extracted from bs7671 iet wiring regulations 18th edition.